Prices incl. VAT plus shipping costs
Free of shipping costs!
In stock. Delivery time approx. 3-4 working days
- Order number: VA101000286
-
Benefits:
- 30 days return policy
- Fast shipping
- Direct purchase from the manufacturer
- Buyer protection: PayPal & Amazon Pay
- Free shipping from 49,- € DE
from 99,- € AT, NL, LU, BE
Flush-Mounted Radio Thermostat Set | VFTM Manual Transmitter & VUP Flush-Mounted Receiver | VASNER
Product features
- Set with VFTM radio thermostat transmitter & VUP flush-mounted receiver
- For manual control of infrared heaters and electric heaters
- Temperature control via practical rotary knob
- Discreet flush-mounted installation of the receiver - no visible cables
- Frost protection function (≥ 3 °C) for safe operation
- Optional night setback: temperature reduction by 3 °C for 8 hours
- Compact design of the transmitter with flexible wall mounting or stand
- Stable radio connection with a range of up to 35 m indoors
- Compatibility: Set can be combined with other VUP flush-mounted & VAP socket receivers
- NO time or weekday programming | purely manual control
Description
The VASNER set consisting of VFTM radio thermostat transmitter and VUP flush-mounted receiver offers simple, manual control for your infrared heaters. The VFTM transmitter impresses with its intuitive operation via a rotary knob, without complicated programming. At the same time, the unobtrusive VUP flush-mounted receiver ensures discreet installation without visible cables - perfect for elegant living room design. Thanks to the frost protection function, the room temperature always remains above 3 °C, and the night setback function reduces energy consumption without sacrificing comfort. The connection between the transmitter and receiver is reliable and allows flexible positioning of the thermostat transmitter in your home.
Note: Please note that this combination does not allow automatic programming of your infrared heating, as would be possible with the VFTB transmitter. This set is ideal for anyone who prefers quick and uncomplicated temperature control.
Technical data
VASNER VFTM radio thermostat transmitter:
- Article name: VASNER VFTM radio thermostat transmitter (manual)
- Dimensions: 8.1 x 8.1 x 3 cm
- Weight: 118g (without stand), 130g (with stand)
- Control: Infrared heaters / electric heaters
- Compatibility: VASNER thermostat receiver VUP (flush-mounted) and VAP (socket)
- Temperature range: +11 to +29 °C
- Frost protection: 3 °C
- Optional night setback: Reduction of the temperature by 3 °C, 8 hours
- Hysteresis: 0.4 °C
- Temperature deviation: ± 1 °C
- Protection class: IP20
- Operating temperature: 0 to +40 °C
- Radio frequency: 433.92 MHz (bidirectional)
- HF power: < 10 mW
- Battery supply: 2× 1.5 V AA alkaline batteries (not included)
VASNER VUP radio thermostat flush-mounted receiver:
- Article: VASNER VUP flush-mounted radio thermostat receiver (2016VUP)
- Dimensions (depth x diameter): 26 x 59 mm for standard 60 mm flush-mounted box
- For controlling electric heaters & infrared heaters
- The receivers have 16A switching capacity. This even makes it possible to connect several heaters to one receiver up to a maximum wattage of approx. 3200 to 3500 watts.
- Power supply 230 V / 50 Hz
- Communication: bidirectional
- Range in the building: max. 35 m
- Consumption: 1 VA
- Sensitivity: < -92 dBm
- Switching element: relay
- Output: Relay, max. 16 A / 250 VAC
- Protection class: IP20
- Operating temperature: 0°C to 40°C
- Frequency: 433.92 MHz
Scope of delivery
- 1 × VASNER VFTM radio thermostat transmitter
- 1 × Mounting accessories (incl. wall bracket and stand)
- 1 × Operating instructions (transmitter)
- 1 × VASNER VUP flush-mounted radio receiver
- 1 × Operating instructions (receiver)
VASNER
MankeTech GmbH
Stahlstraße 27
33415 Verl, Germany
Mail: info@vasner.com
Suitable for: | Electric heaters |
Operating modes: | Manual |
Number of quick dial modes: | 1 (Nacht) |
Temperature changes per day: | 0 |
Temperature range: | 11 °C bis 29 °C |
Temperature adjustable in: | 1 °C Schritten |
Temperature accuracy: | +/- 0,4 °C |
Frost protection function: | Yes (3 °C fixed value) |
Child lock / key lock: | No |
Backup memory: | Nein |
Integrated consumption measurement: | No |
IP protection class: | IP20 |
Enthaltene Sprachen / Languages included:
BG – BULGARIAN: ВАЖНИ ИНСТРУКЦИИ ЗА БЕЗОПАСНОСТ
CS – CZECH: DŮLEŽITÉ BEZPEČNOSTNÍ POKYNY
DA – DANISH: VIGTIGE SIKKERHEDSINSTRUKTIONER
DE – GERMAN: WICHTIGE SICHERHEITSHINWEISE
EL – GREEK: ΣΗΜΑΝΤΙΚΕΣ ΟΔΗΓΙΕΣ ΑΣΦΑΛΕΙΑΣ
EN – ENGLISH: IMPORTANT SAFETY INSTRUCTIONS
ES – SPANISH: INSTRUCCIONES DE SEGURIDAD IMPORTANTES
ET – ESTONIAN: OLULISED OHUTUSJUHISED
FI – FINNISH: TÄRKEITÄ TURVALLISUUSOHJEITA
FR – FRENCH: CONSIGNES DE SÉCURITÉ IMPORTANTES
GA – IRISH: TREORACHA TÁBHACHTACHA SÁBHÁILTEACHTA
HR – CROATIAN: VAŽNE SIGURNOSNE UPUTE
HU – HUNGARIAN: FONTOS BIZTONSÁGI UTASÍTÁSOK
IT – ITALIAN: IMPORTANTI ISTRUZIONI DI SICUREZZA
LT – LITHUANIAN: SVARBIOS SAUGOS INSTRUKCIJOS
LV – LATVIAN: SVARĪGAS DROŠĪBAS INSTRUKCIJAS
MT – MALTESE: STRUZZJONIJIET IMPORTANTI DWAR IS- SIGURTÀ
NL – DUTCH: BELANGRIJKE VEILIGHEIDSINSTRUCTIES
PL – POLISH: WAŻNE INSTRUKCJE BEZPIECZEŃSTWA
PT – PORTUGUESE: INSTRUÇÕES DE SEGURANÇA IMPORTANTES
RO – ROMANIAN: INSTRUCȚIUNI IMPORTANTE DE SIGURANȚĂ
SK – SLOVAK: DÔLEŽITÉ BEZPEČNOSTNÉ POKYNY
SL – SLOVENIAN: POMEMBNA VARNOSTNA NAVODILA
SV – SWEDISH: VIKTIGA SÄKERHETS INSTRUKTIONER