Prices incl. VAT plus shipping costs
Free of shipping costs!
In stock. Delivery time approx. 3-4 working days
- Order number: VA101000287
-
Benefits:
- 30 days return policy
- Fast shipping
- Direct purchase from the manufacturer
- Buyer protection: PayPal & Amazon Pay
- Free shipping from 49,- € DE
from 99,- € AT, NL, LU, BE
Plug-In Radio Thermostat Set for Socket Outlet | VFTM Manual Transmitter & VAP Socket Receiver | VASNER
Product features
- Set consisting of VFTM radio thermostat transmitter & VAP socket receiver
- Manual control of infrared heaters and electric heaters
- Temperature control via user-friendly rotary knob on the transmitter
- Flexible connection of the receiver to any standard socket outlet - without installation effort
- Frost protection function (≥ 3 °C) for reliable operation
- Optional night setback: temperature reduction by 3 °C for 8 hours
- Compact, versatile design of the transmitter with wall bracket or stand
- Stable wireless connection with a range of up to 35 m indoors
- Compatible with other VAP socket and VUP flush-mounted receivers
- Note: This set does not offer automatic programming - ideal for quick and easy control.
Description
The VASNER radio thermostat set VFTM transmitter and VAP socket receiver combines simple handling and flexible application options for your infrared heaters. The VFTM radio transmitter allows you to control the temperature precisely using a rotary knob, without complicated programming. At the same time, the VAP socket receiver is effortlessly connected between the radiator and the socket, allowing flexible positioning - ideal for any living area. Thanks to the frost protection function, the room temperature is reliably kept above 3 °C. In addition, the optional night setback reduces energy consumption without sacrificing living comfort. The stable radio connection ensures reliable control with a range of up to 35 m indoors. This set is aimed at users who value uncomplicated operation and rapid operational readiness. With its compact design, the transmitter blends discreetly into any living environment.
Note: This set does not offer automatic programming - ideal for quick and uncomplicated control.
Technical data
VASNER VFTM radio thermostat transmitter:
- Article name: VASNER VFTM radio thermostat transmitter (manual)
- Dimensions: 8.1 x 8.1 x 3 cm
- Weight: 118g (without stand), 130g (with stand)
- Control: Infrared heaters / electric heaters
- Compatibility: VASNER thermostat receiver VUP (flush-mounted) and VAP (socket)
- Temperature range: +11 to +29 °C
- Frost protection: 3 °C
- Optional night setback: Reduction of the temperature by 3 °C, 8 hours
- Hysteresis: 0.4 °C
- Temperature deviation: ± 1 °C
- Protection class: IP20
- Operating temperature: 0 to +40 °C
- Radio frequency: 433.92 MHz (bidirectional)
- HF power: < 10 mW
- Battery supply: 2× 1.5 V AA alkaline batteries (not included)
VASNER VAP radio thermostat socket receiver:
- Product: VASNER radio thermostat socket receiver (2016VAP)
- For controlling infrared heaters & electric heaters
- The receivers have 16A switching capacity. This even makes it possible to connect several heaters to one receiver up to a maximum wattage of approx. 3200 to 3500 watts.
- Communication: bidirectional
- Protection class: IP20
- Range in the building: max. 35 m
- Power supply: 230 V / 50 Hz
- Consumption: 1 VA
- Sensitivity: -95 dBm
- Switching element: Relay
- Output: 16 A / 250 VAC
- Operating temperature: 0°C to 40°C
- Dimensions (H x W x D): 13 x 6 x 4 cm
Scope of delivery
- 1 × VASNER VFTM radio thermostat transmitter
- 1 × Mounting accessories (incl. wall bracket and stand)
- 1 × Operating instructions (transmitter)
- 1 × VASNER VAP radio socket receiver
- 1 × Operating instructions (receiver)
VASNER
MankeTech GmbH
Stahlstraße 27
33415 Verl, Germany
Mail: info@vasner.com
Suitable for: | Electric heaters |
Operating modes: | Manual |
Number of quick dial modes: | 1 (Nacht) |
Temperature changes per day: | 0 |
Temperature range: | 11 °C bis 29 °C |
Temperature adjustable in: | 1 °C Schritten |
Temperature accuracy: | +/- 0,4 °C |
Frost protection function: | Yes (3 °C fixed value) |
Child lock / key lock: | No |
Backup memory: | Nein |
Integrated consumption measurement: | No |
IP protection class: | IP20 |
Enthaltene Sprachen / Languages included:
BG – BULGARIAN: ВАЖНИ ИНСТРУКЦИИ ЗА БЕЗОПАСНОСТ
CS – CZECH: DŮLEŽITÉ BEZPEČNOSTNÍ POKYNY
DA – DANISH: VIGTIGE SIKKERHEDSINSTRUKTIONER
DE – GERMAN: WICHTIGE SICHERHEITSHINWEISE
EL – GREEK: ΣΗΜΑΝΤΙΚΕΣ ΟΔΗΓΙΕΣ ΑΣΦΑΛΕΙΑΣ
EN – ENGLISH: IMPORTANT SAFETY INSTRUCTIONS
ES – SPANISH: INSTRUCCIONES DE SEGURIDAD IMPORTANTES
ET – ESTONIAN: OLULISED OHUTUSJUHISED
FI – FINNISH: TÄRKEITÄ TURVALLISUUSOHJEITA
FR – FRENCH: CONSIGNES DE SÉCURITÉ IMPORTANTES
GA – IRISH: TREORACHA TÁBHACHTACHA SÁBHÁILTEACHTA
HR – CROATIAN: VAŽNE SIGURNOSNE UPUTE
HU – HUNGARIAN: FONTOS BIZTONSÁGI UTASÍTÁSOK
IT – ITALIAN: IMPORTANTI ISTRUZIONI DI SICUREZZA
LT – LITHUANIAN: SVARBIOS SAUGOS INSTRUKCIJOS
LV – LATVIAN: SVARĪGAS DROŠĪBAS INSTRUKCIJAS
MT – MALTESE: STRUZZJONIJIET IMPORTANTI DWAR IS- SIGURTÀ
NL – DUTCH: BELANGRIJKE VEILIGHEIDSINSTRUCTIES
PL – POLISH: WAŻNE INSTRUKCJE BEZPIECZEŃSTWA
PT – PORTUGUESE: INSTRUÇÕES DE SEGURANÇA IMPORTANTES
RO – ROMANIAN: INSTRUCȚIUNI IMPORTANTE DE SIGURANȚĂ
SK – SLOVAK: DÔLEŽITÉ BEZPEČNOSTNÉ POKYNY
SL – SLOVENIAN: POMEMBNA VARNOSTNA NAVODILA
SV – SWEDISH: VIKTIGA SÄKERHETS INSTRUKTIONER